Selection Guide
Timers
| On Delay |
| Control |
Power |
Output |
Time |
Mounting |
Model |
|
Isolated
|
AC
|
Relay / SS(1)
|
0.06-500 sec
|
Base
|
1010
|
|
Relay
|
0.06-500 sec
|
12 pin plug
|
1012
|
|
Relay
|
0.06-500 sec
|
Base
|
1013
|
Relay w/ Instant(3)
|
0.06-500 sec
|
Base
|
1014
|
|
AC/DC
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
|
Pulse
|
AC/DC
|
Relay
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1090
|
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
Power
|
AC/DC
|
Relay
|
0.025 - 300 sec
|
Base
|
1017SP7
|
|
Relay
|
0.02 - 500 sec
|
Plug
|
1019
|
|
Relay
|
Fixed .025 - 1200 sec
|
Base
|
1020
|
|
Relay
|
Fixed .025 - 1200 sec
|
Base
|
1025
|
|
Relay
|
0.025 - 300 sec
|
Base
|
1026
|
|
Relay
|
0.025 - 2000 sec
|
Plug
|
1071
|
Relay w/ Instant(3)
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1073
|
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
|
Solid State
|
0.1 - 10230 sec
|
Block
|
2110
|
|
Totalized(4)
|
AC/DC
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
| Off Delay |
| Control |
Power |
Output |
Time |
Mounting |
Model |
|
Isolated
|
AC
|
Relay / SS(1)
|
0.06-500 sec
|
Base
|
1010
|
|
Relay
|
0.06-500 sec
|
12 pin plug
|
1012
|
|
Relay
|
0.06-500 sec
|
Base
|
1013
|
Relay w/ Instant(3)
|
0.06-500 sec
|
Base
|
1014
|
|
AC/DC
|
Relay
|
0.06 - 1000 sec |
Plug
|
1018
|
|
Relay
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1090
|
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
|
Power
|
AC/DC
|
Relay
|
0.04 sec - 10 min
|
Plug
|
1081
|
| Interval |
| Control |
Power |
Output |
Time |
Mounting |
Model |
|
Isolated
|
AC
|
Relay / SS(1)
|
0.06-500 sec
|
Base
|
1010
|
|
Relay
|
0.06-500 sec
|
Base
|
1013
|
|
AC/DC
|
Relay
|
0.06 - 1000 sec |
Plug
|
1018
|
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
|
Solid State
|
0.1 - 10230 sec
|
Block
|
2115
|
|
Pulse
|
AC
|
Relay / SS(1)
|
0.06-500 sec
|
Base
|
1010
|
|
Relay
|
0.06-500 sec
|
12 pin plug
|
1012
|
|
Relay
|
0.06-500 sec
|
Base
|
1013
|
|
AC/DC
|
Relay
|
0.06 - 1000 sec |
Plug
|
1018
|
|
Relay
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1090
|
|
Power
|
AC/DC
|
Relay w/ Instant(3)
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1073
|
| One Cycle |
| Control |
Power |
Output |
Time |
Mounting |
Model |
|
Isolated
|
AC
|
Relay
|
0.06 - 500 sec(5)
|
Base
|
1030
|
|
Relay
|
0.06 - 500 sec(5)
|
12 pin plug
|
1032
|
|
Pulse
|
AC
|
Relay
|
0.06 - 500 sec(5)
|
Base
|
1030
|
|
Relay
|
0.06 - 500 sec(5)
|
12 pin plug
|
1032
|
|
AC/DC
|
Relay
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1090
|
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2,5)
|
Plug / Panel
|
1096
|
|
Power
|
AC/DC
|
Relay w/ Instant(3)
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1073
|
|
Totalized(4)
|
AC/DC
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2,5)
|
Plug / Panel
|
1096
|
| Repeat Cycle |
| Control |
Power |
Output |
Time |
Mounting |
Model |
|
Isolated
|
AC
|
Relay
|
0.06 - 500 sec(5)
|
Base
|
1060
|
|
Solid State
|
0.06 - 500 sec(5)
|
Base
|
1061
|
|
Pulse
|
AC/DC
|
Relay
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1090
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2)
|
Plug / Panel
|
1094
|
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2,5)
|
Plug / Panel
|
1096
|
|
Power
|
AC/DC
|
Relay
|
0.1 sec - 500 hr(2,5)
|
Plug / Panel
|
1068
|
Relay w/ Instant(3)
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1073
|
|
Totalized(4)
|
AC/DC
|
Relay / SS(1)
|
0.001 sec - 9,999 hr(2,5)
|
Plug / Panel
|
1096
|
| On Delay/Off Delay |
| Control |
Power |
Output |
Time |
Mounting |
Model |
|
Isolated
|
AC
|
Relay
|
0.06 - 500 sec(5)
|
Base
|
1030
|
|
Relay
|
0.06 - 500 sec(5)
|
12 pin plug
|
1032
|
|
AC/DC
|
Relay
|
0.1 sec - 500 hr(2)
|
Plug / Panel
|
1090
|
|
Max. Pulses |
Range |
Power |
Input |
Output |
Mounting |
Model |
|
1000 ppm
|
0.1 sec - 500 hr(2)
|
AC / DC
|
Contacts
|
Relay
|
Plug / Panel
|
1090
|
|
1080 ppm
|
0.06 - 100 sec
|
AC / DC
|
Contacts
|
Relay
|
Base
|
1214
|
|
1080 ppm
|
0.06 - 100 sec
|
AC / DC
|
24 VDC
|
Relay
|
Base
|
1217C
|
|
10000 ppm
|
5 - 7500 ppm(2)
|
AC / DC
|
Self contained
|
Solid State
|
Block
|
1248A
|
|
2,400 ppm
|
0.06 - 500 sec
|
AC
|
Contacts / 120 VAC
|
Relay / SS(1)
|
Base
|
1260
|
|
108,000 ppm
|
0.02 - 1000 sec
|
AC
|
Contacts / 120 VAC / 12 VDC
|
Relay
|
Base
|
1262
|
| Adjustment Range |
Power supply |
Input |
Output |
Model |
|
0.06 - 100 sec
|
120 VAC or 24VAC/DC
|
24 VDC
|
Relay
|
1217C
|
|
0.06 - 500 sec
|
120 VAC
|
120 VAC
|
Relay / SS(1)
|
1260
|
|
0.02 - 1000 sec
|
120 VAC
|
120 VAC or 12 VDC
|
Relay
|
1262
|
| Input Mode |
Function |
Power |
Output |
Mount |
Model |
Dual Input / Contacts
|
Multi-Function
|
AC / DC
|
Relay / SS(1)
|
Plug / Panel
|
1105C
|
|
Power
|
Hourmeter
|
DC
|
Display
|
Panel
|
1120H
|
| Feature |
Power |
Output |
Mount |
Model |
|
Voltage / Resistance
|
AC
|
Relay
|
Base
|
1213
|
|
Compact
|
AC
|
Solid State
|
Plug
|
1230
|
Built-in Timer 0.05-1 sec
|
AC / DC
|
Relay
|
Base
|
1232
|
|
Range Detector
|
AC / DC
|
Relay
|
Base
|
1234
|
Liquid Level Detector
|
AC
|
Solid State
|
Base
|
LLD-100
|
Notes:
- Relay / SS = relay standard, solid state optional.
- Selectable time ranges.
- Timed and instant output.
- Non-volatile, retains time/count when power is removed.
- Two adjustable time periods.
|
|