• Input
    Voltage:
    120VAC
    Frequency:
    50/60 Hz
    Tolerance (voltage):
    ± 10% of nominal
    Power Consumption:
    10 VA maximum
    Transient Protection:
    Isolation transformer
  • Output
    Type:
    Electromechanical relay
    Rating:
    10A - 1/6 HP at 120VAC, 1/3 HP at 240VAC
  • Timing
    Available Types:
    Motion Detector
    Repeat Accuracy:
    ± 1% of setting
    Indication:
    LED indicates unit timing and outputenergized
    Timing Ramp:
    .02 sec minimum time - 1MΩ/sec0.06 sec minimum time - 100KΩ/sec0.5 sec minimum time - 10KΩ/sec
    Time Range:
    0.02 to 1000 secs in 13 ranges
    Range Tolerance:
    ≤ 10% at max., ≤ 0% at min.
    Control Terminals:
    A-B-C-D-E-F
    Voltage Present at Control Terminals:
    A - C : Same as input voltage B - C : 120VAC pulseD - E - F : 12VDCD - E : 12VDC pulse
  • Physical
    Operating Temp:
    0° to 50° C (32° to 120° F)
    Timing Variation vs. Temp:
    ± 5% maximum
    Mounting:
    Base Mount
    Termination:
    Terminal blocks on face of timer
    Housing:
    Metal

Wiring Terminal Location

1262 Sensor Wiring

Dimensions

1262 Sensor Dimensions

Ordering Data

1262 Sensor Ordering