• Input
    Voltage:
    24VAC, 120 VAC or 240 VAC
    Frequency:
    50/60 Hz
    Tolerance (voltage):
    ± 15% of nominal
    Power Consumption:
    2VA maximum
    Transient Protection:
    Protected
  • Output
    Type:
    Solid State N.O. Zero Voltage Crossing
    Rating:
    1A @ 240VAC/DC max.
    Voltage Drop:
    <1.6 volts at 1A
  • Timing
    Available Types:
    On Delay
    Time Range:
    1 minute to 10230 days in 3 ranges
    Range Tolerance:
    <250 msec per application of power
    Control:
    Power applied to input initiates timing cycle
  • Physical
    Operating Temp:
    0°C to 70°C (-32° to 155° F) extended temperature range available - contact factory
    Mounting:
    Surface with #8 or #10 screw
    Termination:
    0.250 inch male quick connect terminals
    Housing:
    Plastic

Wiring Terminal Location

2210 Timer Wiring

Dimensions

2210 Timer Dimensions

Ordering Data