The following guide can help you choose Kanson ISSC products based on your specifications. If you need additional help ordering product, please contact us or download our PDF catalog.

 

On Delay
ControlPowerOutputTimeMountingModel
IsolatedACRelay / SS(1)0.06 – 500 secBase1010
IsolatedACRelay0.06 – 500 sec12 pin plug1012
IsolatedACRelay0.06 – 500 secBase1013
IsolatedACRelay w / Instant(3)0.06 – 500 secBase1014
IsolatedAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
PulseAC/DCRelay0.1 sec – 500 hr(2)Plug / Panel1090
PulseAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
PowerAC/DCRelay0.025 – 300 secBase1017SP7
PowerAC/DCRelay0.02 – 500 secPlug1019
PowerAC/DCRelayFixed .025 – 1200 secBase1020
PowerAC/DCRelayFixed .025 – 1200 secBase1025
PowerAC/DCRelay0.025 – 300 secBase1026
PowerAC/DCRelay0.025 – 2000 secPlug1071
PowerAC/DCRelay w / Instant(3)0.1 sec – 500 hr(2)Plug / Panel1073
PowerAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
PowerAC/DCSolid State0.1 – 10230 secBlock2110
Totalized(4)AC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
Off Delay
ControlPowerOutputTimeMountingModel
IsolatedACRelay / SS(1)0.06-500 secBase1010
IsolatedACRelay0.06-500 sec12 pin plug1012
IsolatedACRelay0.06-500 secBase1013
IsolatedACRelay w / Instant(3)0.06-500 secBase1014
IsolatedAC/DCRelay0.06 – 1000 secPlug1018
IsolatedAC/DCRelay0.1 sec – 500 hr(2)Plug / Panel1090
IsolatedAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
PowerAC/DCRelay0.04 sec – 10 minPlug1081
Interval
ControlPowerOutputTimeMountingModel
IsolatedACRelay / SS(1)0.06 – 500 secBase1010
IsolatedACRelay0.06 – 500 secBase1013
IsolatedAC/DCRelay0.06 – 1000 secPlug1018
IsolatedAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
IsolatedAC/DCSolid State0.1 – 10230 secBlock2115
PulseACRelay / SS(1)0.06 – 500 secBase1010
PulseACRelay0.06 – 500 sec12 pin plug1012
PulseACRelay0.06 – 500 secBase1013
PulseAC/DCRelay0.06 – 1000 secPlug1018
PulseAC/DCRelay0.1 sec – 500 hr(2)Plug / Panel1090
PowerAC/DCRelay w / Instant(3)0.1 sec – 500 hr(2)Plug / Panel1073
One Cycle
ControlPowerOutputTimeMountingModel
IsolatedACRelay0.06 – 500 sec(5)Base1030
IsolatedACRelay0.06 – 500 sec(5)12 pin plug1032
PulseACRelay0.06 – 500 sec(5)Base1030
PulseACRelay0.06 – 500 sec(5)12 pin plug1032
PulseAC/DCRelay0.1 sec – 500 hr(2)Plug / Panel1090
PulseAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2,5)Plug / Panel1096
PowerAC/DCRelay w / Instant(3)0.1 sec – 500 hr(2)Plug / Panel1073
Totalized(4)AC/DCRelay / SS(1)0.001 sec – 9,999 hr(2,5)Plug / Panel1096
Repeat Cycle
ControlPowerOutputTimeMountingModel
IsolatedACRelay0.06 – 500 sec(5)Base1060
IsolatedACSolid State0.06 – 500 sec(5)Base1061
PulseAC/DCRelay0.1 sec – 500 hr(2)Plug / Panel1090
PulseAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2)Plug / Panel1094
PulseAC/DCRelay / SS(1)0.001 sec – 9,999 hr(2,5)Plug / Panel1096
PowerAC/DCRelay0.1 sec – 500 hr(2,5)Plug / Panel1068
PowerAC/DCRelay w / Instant(3)0.1 sec – 500 hr(2)Plug / Panel1073
Totalized(4)AC/DCRelay / SS(1)0.001 sec – 9,999 hr(2,5)Plug / Panel1096
On Delay/Off Delay
ControlPowerOutputTimeMountingModel
IsolatedACRelay0.06 – 500 sec(5)Base1030
IsolatedACRelay0.06 – 500 sec(5)12 pin plug1032
IsolatedAC/DCRelay0.1 sec – 500 hr(2)Plug / Panel1090
Motion Detection
Max. PulsesRangePowerInput ControlOutputMountingModel
1000 ppm0.1 sec – 500 hr(2)AC/DCContactsRelayPlug / Panel1090
1080 ppm0.06 – 100 secAC/DCContactsRelayBase1214
1080 ppm0.06 – 100 secAC/DC24 VDCRelayBase1217C
10000 ppm5 – 7500 ppm(2)AC/DCSelf containedSolid StateBlock1248A
2,400 ppm0.06 – 500 secACContacts /
120 VAC
Relay / SS(1)Base1260
108,000 ppm0.02 – 1000 secACContacts / 120 VAC / 12 VDCRelayBase1262
PLC Watchdog
Adjustment RangePower supplyInputOutputModel
0.06 – 100 sec120 VAC or 24VAC/DC24 VDCRelay1217C
0.06 – 500 sec120 VAC120 VACRelay / SS(1)1260
0.02 – 1000 sec120 VAC120 VAC or 12 VDCRelay1262
Counter
Input ModeFunctionPowerOutputMountModel
Dual Input / ContactsMulti-FunctionAC / DCRelay / SS(1)Plug / Panel1105C
PowerHourmeterDCDisplayPanel1120H
Resistance / Voltage Detection
FeaturePowerOutputMountModel
Voltage / ResistanceACRelayBase1213
CompactACSolid StatePlug1230
Built-in Timer 0.05-1 secAC / DCRelayBase1232
Range DetectorAC / DCRelayBase1234
Liquid Level DetectorACSolid StateBaseLLD-100

Notes:
Relay / SS = relay standard, solid state optional.
Selectable time ranges.
Timed and instant output.
Non-volatile, retains time/count when power is removed.
Two adjustable time periods.